 Lower Mantle
 Lower Mantle If chopped firewood is used as 
the fuel, no funnel is needed. If 
wood chips are used as the 
fuel, the funnel with correct 
inclination is needed. If the 
inclination is not correct the 
wood chips easily form an arch 
and stick (burn) on the inner 
side of the funnel A correctly 
designed funnel makes the fuel 
flow smoothly into the 
combustion chamber and 
assists drying of the fuel. The 
correct inclination for the 
funnel is 60° and the diameter 
of the lower part for 4 liter ICE 
is 200 mm. The diameter of the 
lower part of the funnel shall 
always be 2/3 of the diameter 
of the combustion chamber. The 
distance between the lower end 
of the funnel and the air nozzle 
plane must be 200 mm.
If chopped firewood is used as 
the fuel, no funnel is needed. If 
wood chips are used as the 
fuel, the funnel with correct 
inclination is needed. If the 
inclination is not correct the 
wood chips easily form an arch 
and stick (burn) on the inner 
side of the funnel A correctly 
designed funnel makes the fuel 
flow smoothly into the 
combustion chamber and 
assists drying of the fuel. The 
correct inclination for the 
funnel is 60° and the diameter 
of the lower part for 4 liter ICE 
is 200 mm. The diameter of the 
lower part of the funnel shall 
always be 2/3 of the diameter 
of the combustion chamber. The 
distance between the lower end 
of the funnel and the air nozzle 
plane must be 200 mm. 
If the wood chips stick (burn) 
on the inner wall of the funnel, 
the funnel must be lifted 
upwards. A guide plate must 
also be welded onto the funnel 
to guide the condensing liquid 
to the collection channel. On 
the inner side of the outer 
cylinder is also a collection 
channel for the condensing 
liquid with a connection to the 
outside. The channel must be 
inclined to make the liquid 
flow to the collection tank. The 
collection tank must be 
gas-tight and spacious enough, 
suitable volume is 10 liter. If the collection channel is not inclined it will soon be stuck 
and the generator will not function properly because the moisture cannot escape from the 
combustion chamber. Inside the lower end of the outer cylinder is a flange for connecting 
the fuel reservoir to the other parts of the generator. To make the installation easy there 
are openings on the outer mantle just where the connecting bolts are placed. The flange 
and the collection channel are welded together on the inside. Due to this the openings on 
the outer mantle do not affect the gas tightness.
The gasket of the fuel reservoir lid is made of silicone tubing or asbestos string treated 
with graphite. The lid is connected to a leaf spring. The force of the spring causes the lid 
to close tightly. The lid serves also as an emergency valve through which the excess 
pressure in the generator can escape if the gas ignites in the combustion chamber or in 
the fuel reservoir.
Translated by Olli.